Autoclave Steam Sterilizer | 25L - oxyaider

Product categories

Autoclave Steam Sterilizer | 25L

Autoclave Steam Sterilizer | 25L

R31,000.00

  • Sterilizing course: Automatic sterilization controlled by computer, easy to operate.
  • Maximum temperature: up to 134 ℃, suit for 4-6 minutes rapidly sterilizing.
  • Safe protection of water lacking.
  • With over-temperature, over-pressure auto-protect device:
  • Fully stainless steel structure.
Qty:
Compare

Description

Steam Sterilizer Autoclave 25L

An autoclave is a machine that uses steam under pressure to kill harmful bacteria, viruses, fungi, and spores on items that are placed inside a pressure vessel. The items are heated to an appropriate sterilization temperature for a given amount of time. The moisture in the steam efficiently transfers heat to the items to destroy the protein structure of the bacteria and spores.

 Autoclave - Oxyaider

WT-24J

Product Description

Specifications:
Sterilizing chamber volume: 24L(φ270×410 mm)
Working pressure: 0.22Mpa
Working temperature: 134℃
Adjustment of temperature: 105-134℃
Timer: 0-60 min
Heat average: ≤ ± 1℃
Power: 1.5 KW / AC220V /110V 50Hz
Sterilizing plate: 340 ×200 × 30 mm ( 3piece )
Dimension: 560 × 350 × 500 mm
Package dimension: 620 × 410 × 570 mm
G.W/N. W: 20/18 kg

Safety protection device:
1. Water-off & over-temperature protection. When the heating element is heating without water, the power supply will be cut.
2. Over-current protection. If the current exceeds the rated value, the power broken circuit will cut power automatically.
3. Safety valve. When the pressure exceeds 0.22Mpa(34Psi), the sterilizer will automatically exhaust to drop the pressure

Maintenance:
l. To ensure the reliability of the steriliza*tion effect chemical indicating piece of biologic indicating piece must be put into the sterilization chamber, together with the: objects to be sterilized. After sterilizing, the sterilization effect can be checked.
2. Safety valve and the exhaust valve are on the top, Safety valve must be checked once every year If it is in malfunction, replace it. If the safety valve is in malfunction during use and the pressure keeps increasing, the power supply must be cut to ensure a safe use.
3. The rubber seal ring is easily aged. If aging causes leakage, the seal ring should be replaced in time.
4. The pressure meter must be standardization every year.
5. The machine must be keeping clean, and protecting the incrustant occurs on the surface, often method is wash it with distilling water once a week.
6. If the overheat protector be damaged, you just take of the round cover on the bottom, and change the protector.

 

Product Color Code: 

Instructions for Use

The autoclave is used to sterilize glassware, metal tools, and liquids (growth media, water, solutions). It kills bacteria and spores through heat and pressure. Most items will be sterilized after 30 minutes at 121°C at 20 psi.

POTENTIAL HAZARDS

-heat and steam burns

-hot fluid scalds

-injury in case of explosion

-exposure to pathogens

PROTECTIVE WEAR

-goggles

-long sleeve pants and shirt

-closed toe shoes

PROTOCOL

Liquid Sample Prep

1. Fill container with liquid to be sterilized

2. Unscrew cap until loosely attached to bottle

3. Put a piece of autoclave tape on the cap

4. Use lab tape with end folded over to label bottle with name and date and contents

NOTES

-do not fill bottle more than half way because the liquid bubbles and will spill over

-do not autoclave an item with the lid closed, there is a risk of explosion

-never put volatile liquids or solvents or corrosive chemicals in the autoclave

Solid Sample Prep

1. Wrap item in tinfoil or cover openings with tinfoil

2. Place autoclave tape on foil

Prepare Autoclave

1. Close water outlet nozzle

2. Fill basin with 600ml distilled water

3. Add item to be sterilized

4. Screw lid on autoclave

5. Set timer to desired time (20-30m)

6. Set exhaust valve in up position to allow air to escape

7. Set temperature to correct position

NOTES

-do not touch side knob, just main knob

Run Autoclave

1. Turn on machine

2. Once steam starts spitting out of exhaust valve (after several minutes), close valves using gloves

3. Check that temperature gets up to 121C

4. Sterilizing light should turn on and timer should start going down

5. Once time is at zero the machine should beep

Stopping Autoclave

1. Turn off the power

2. Use a glove to open the steam

3. Once the pressure is at zero

4. Open the water outlet

5. Open the autoclave

6. Use gloves to remove item and close lid

7. Close lid on any liquid bottles and check that autoclave tape turned black

NOTES

-items will be hot, do not leave where they could burn someone

-let items cool to room temperature before moving to shelf

-do not autoclave plastics unless they explicitly say they can be autoclaved

Pre-Order

Thank you for visiting our Pre-Order page!

For the products not available in the warehouse, we offer Pre-order serivice.

It take about 3 weeks or at most 2 months for you to get the product, depends on production time.