CONTEC CMS70A Desktop Pulse Oximeter

CONTEC CMS70A Desktop Pulse Oximeter

R7,034.20

Or split into 4x interest-free payments Learn more
Qty:
Brand:

Description

CONTEC CMS70A Desktop Pulse Oximeter

CONTECMED CMS70A Pulse Oximeter pulse oxygen saturation SPO2 Monitor Heart Rate Monitor Pulse Meter | Lazada PH

Principle of the CMS70A Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology, the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.

Features:

  • Operation of the product is simple ,low power consumption
  • SpO2 value display
  • Pulse rate value display, bar graph display
  • PI display
  • Pulse waveform display
  • Menu operation
  • Screen brightness can be changed
  • The display mode can be changed
  • Pulse rate sound indication, it can be turned on or turned off
  • With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable
  • Battery capacity indication
  • Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function
  • Connected with an external oximeter probe
  • Data storage function,and the storage data can be uploaded to computer
  • Real-time data can be transmitted to computers

Specification

Product Parameters

 

Display mode : TFT Screen and LED display optional
Screen Resolution : 320*240
SpO2 Measuring Range : 0%~100%(the resolution is 1%)
Accuracy : 70%~100%: ±2%, Below 70% unspecified.
PR Measuring Range : 30bpm~250bpm(the resolution is 1bpm)
Measurement Performance in Weak Filling Condition : SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light : The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption : About 350mA
Voltage : AC 100~240V, 50/60HZ
Battery working hour : after the device built-in battry finished the charge,it’s continuous working time is not less than 1 hour

Performance:

  • Display Mode: TFT Screen and LED display
  • Screen Resolution: 320*240
  • SpO2 Measuring Range: 0%~100%(the resolution is 1%)
  • Accuracy: 70%~100%: ±2%, Below 70% unspecified.
  • PR Measuring Range: 30bpm~250bpm(the resolution is 1bpm)
  • Accuracy: ±2bpm or ±2% (select larger)
  • Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
  • Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
  • Power Consumption: About 350mA
  • Voltage:AC 100~240V, 50/60HZ
  • Power Supply: Built-in recharge Li-Polymer
  • Battery working hour: after the device built-in battry finished the charge,it’s continuous working time is not less than 1 hour
  • Safety Type:II device, BF Type